Weight transmitters

TLB4
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 RS485
DIGITAL WEIGHT TRANSMITTER ( RS485 )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 CANOPEN
DIGITAL WEIGHT TRANSMITTER (RS485 – CANopen )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 DEVICENET
DIGITAL WEIGHT TRANSMITTER (RS485 – DeviceNet )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 CC-LINK
DIGITAL WEIGHT TRANSMITTER (RS485 – CC-Link )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 PROFIBUS
DIGITAL WEIGHT TRANSMITTER (RS485 – PROFIBUS )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 PROFINET IO
DIGITAL WEIGHT TRANSMITTER (RS485 – PROFINET IO)

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 ETHERNET/IP
DIGITAL WEIGHT TRANSMITTER (RS485 – Ethernet/IP )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Two Ethernet /IP ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 MODBUS/TCP
DIGITAL WEIGHT TRANSMITTER (RS485 – Modbus/TCP )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Back panel mounting on Omega/DIN rail
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 ETHERNET TCP/IP
DIGITAL WEIGHT TRANSMITTER (RS485 – Ethernet TCP/IP )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 ETHERCAT
DIGITAL WEIGHT TRANSMITTER (RS485 – EtherCAT )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 POWERLINK
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
TLB4 SERCOS III
DIGITAL WEIGHT TRANSMITTER (RS485 – SERCOS III )

4 independent reading channels for load cells (individual load cell monitoring, total weight displaying, digital equalization).

  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for front/back panel
Data Sheet
LCB
UNIVERSAL LOAD CELLS DIGITIZER

LCB Digitizer transforms an analog load cell (output mV/V) into digital and can also be used on existing load cells or strain gauge sensors. Designed for an assembly/wiring integral with the load cell body, it can be connected by fieldbus to PLCs of the most important international brands.

  • Optional fieldbuses: PROFINET IO, Ethernet/IP, Ethernet TCP/IP, Modbus TCP, PROFIBUS DP, EtherCAT, POWERLINK, CANopen, CC-Link, CC-Link IE, SERCOS III, IO-LINK.
  • Micro USB port
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V (optional)
  • RS485 port (optional)
  • Direct connection between RS485 and RS232 without converter.
  • 2 logic inputs, 3 relay outputs
  • Single loading batchings, max 99 formulas
Data Sheet
TLKWF
WiFi DIGITAL WEIGHT TRANSMITTER ( RS232 – RS485 )
  • Wifi module for wireless connection via integrated web server (for remote management to PC, smartphone, tablet, etc.) or via Modbus RTU/Laumas ASCII protocol.
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • Connectable to others TLKWF devices and W series Laumas instruments with OPZW1RADIO optional
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
Data Sheet
TLK
DIGITAL WEIGHT TRANSMITTER ( RS232 – RS485 )
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 digital inputs, 4 relay digital outputs
  • 1 load cell input
  • Wall mounting
Data Sheet
MODWF
WiFi / SERIAL TRANSCEIVER ( RS232 – RS485 )

WiFi communication interface device between two serial devices.

  • Wifi module for wireless connection via Modbus RTU, Laumas ASCII protocol
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • Connectable to others MODWF devices devices and W series Laumas instruments with OPZW1RADIO optional
  • Wall mounting
Data Sheet
TLB
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 )
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB 485
DIGITAL WEIGHT TRANSMITTER ( RS485 )
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB CANOPEN
DIGITAL WEIGHT TRANSMITTER (RS485 – CANopen )
  • CANopen port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB DEVICENET
DIGITAL WEIGHT TRANSMITTER (RS485 – DeviceNet )
  • DeviceNet port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB CC-LINK
DIGITAL WEIGHT TRANSMITTER (RS485 – CC-Link )
  • CC-Link port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB PROFI
DIGITAL WEIGHT TRANSMITTER (RS485 – PROFIBUS )
  • PROFIBUS DP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB PROFINET IO
DIGITAL WEIGHT TRANSMITTER (RS485 – PROFINET IO)
  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB ETHERNET/IP
DIGITAL WEIGHT TRANSMITTER (RS485 – Ethernet/IP )
  • Ethernet /IP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB MODBUS/TCP
DIGITAL WEIGHT TRANSMITTER (RS485 – Modbus/TCP )
  • Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB ETHERNET TCP/IP
DIGITAL WEIGHT TRANSMITTER (RS485 – Ethernet TCP/IP )
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB ETHERCAT
DIGITAL WEIGHT TRANSMITTER (RS485 – EtherCAT )
  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB POWERLINK
DIGITAL WEIGHT TRANSMITTER (RS485 – POWERLINK )
  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
TLB SERCOS III
DIGITAL WEIGHT TRANSMITTER (RS485 – SERCOS III )
  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 3 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Back panel mounting on Omega/DIN rail
Data Sheet
CLM8
INTELLIGENT JUNCTION BOXES – 8 CHANNELS FOR LOAD CELLS

The CLM8 series offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • OIML R76:2006 approved, class III, 3×5000 divis. 0.4μV/VSI

Available versions:

  • IP67 stainless steel box: 200x148x45 mm; 8+2 cable glands – plugs.
  • IP67 ABS box: 210x130x40 mm; 4/8+3 cable glands – plugs, 4/8+2 PVC end fittings.
  • IP67 polycarbonate box: 170x140x95 mm; 4/8+2 cable glands – plugs, 4/8+2 PVC end fittings.
  • Omega/DIN rail mounting version: 125x92x52 mm.
  • Board only: 151x72x30 mm.
Data Sheet
TLM8
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 ) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 CANOPEN
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, CANopen) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave CANopen port, max 99 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 DEVICENET
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, DeviceNet) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave DeviceNet port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 CC-LINK
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, CC-Link) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave CC-Link port, max 64 instruments
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 PROFIBUS
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, PROFIBUS) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave PROFIBUS DP port (max 32 instruments without line repeaters; max 126 instruments with line repeaters)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 PROFINET IO
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, PROFINET IO) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Two PROFINET IO ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 ETHERNET/IP
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, Ethernet/IP) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave Ethernet /IP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 MODBUS/TCP
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, Modbus/TCP) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Slave Modbus/TCP port
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 ETHERCAT
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, EtherCAT) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Two EtherCAT ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 ETHERNET TCP/IP
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, Ethernet TCP/IP) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Ethernet TCP/IP port for remote management (connectable to your PC, smartphone, tablet, etc. via web)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 POWERLINK
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, POWERLINK) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Two POWERLINK ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLM8 SERCOS III
DIGITAL-ANALOG WEIGHT TRANSMITTER (RS485, SERCOS III) 8 CHANNELS FOR LOAD CELLS

The TLM8 offers the benefits and performance of an advanced digital weighing system even using analog load cells. 8 independent reading channels for load cells. Digital equalization. Automatic diagnostics.

  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V
  • Two SERCOS III ports
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 3 logic inputs, 5 relay outputs
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • Mounting on Omega/DIN rail for back panel or junction box
Data Sheet
TLE
ANALOG WEIGHT TRANSMITTER ( RS485 )
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU)
  • Simple zero setting and full scale through digital rotary control (Encoder)
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
Data Sheet
TLS 485
DIGITAL WEIGHT TRANSMITTER ( RS485 )
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 2 optorelays logic outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
Data Sheet
WEBLAU
WEB SERVER MASTER FOR W AND TLB SERIES (max 8)
  • Ideal for supervision, management and remote control of the W series weight indicators and TLB series weight transmitters (max 8 instruments)
  • RS485 port (Modbus RTU)
  • Ethernet TCP/IP port for remote management via internet from PC, smartphone or tablet, etc.
  • Back panel mounting on Omega/DIN rail

The WEBLAU device is a useful support for all installers/dealers of Laumas weighing instruments as it makes easier the remote maintenance, allowing to control wherever, the status of the instruments connected to RS485 including the possible anomalies.

Data Sheet
TLS
DIGITAL-ANALOG WEIGHT TRANSMITTER ( RS485 )
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 2 optorelays logic outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
Data Sheet
THFPROFI
DIGITAL WEIGHT TRANSMITTER ( RS485 – PROFIBUS )
  • Slave Profibus DP port (max 32 instruments without line repeaters; max 126 instruments with line repeaters)
  • RS485 port (Modbus RTU/Laumas ASCII protocol)
  • 1 logic input, 1 relay output
  • OIML R76:2006 approved, class III, 10000 divis. 0.2μV/VSI
  • OIML R61 – WELMEC Guide 8.8:2011 (M.I.D.)
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
Data Sheet
TLU
DIGITAL-ANALOG LOAD LIMITING DEVICE/INDICATOR
  • Suitable for lifting systems
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V (optional)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 4 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
Data Sheet
TLL
DIGITAL WEIGHT TRANSMITTER ( RS232 – RS485 )
  • Synchronous weight transmission for PLCs without serial port
  • 16-bit Analog output: 0/4-20 mA; 0-5/10 V; ±5/10 V (optional)
  • RS232 and RS485 ports (Modbus RTU/Laumas ASCII protocol)
  • 2 logic inputs, 4 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Box versions: IP67, IP67 ATEX II 3GD
Data Sheet
CASTLATEX
IP67 CASE WITH TRANSPARENT COVER

For weight transmitter series TLE

  • ATEX II 3GD approved
  • Dimensions 170x140x95 mm; centre distance 122×152 mm
  • 6 PG9 cable glands
Data Sheet
CASTLTASTATEX
IP67 CASE WITH EXTERNAL KEYPAD

For weight transmitters: TLS, TLS485, TLU, TLL, THFPROFI

  • ATEX II 3GD approved
  • Dimensions 170x140x95 mm; centre distance 122×152 mm
  • 6 PG9 cable glands
Data Sheet
TPS – JOLLYTPS
ANALOG WEIGHT TRANSMITTER
  • Analog output: 0/4-20 mA; 0-10V
  • Mounting on Omega/DIN rail for back panel or junction box
  • IP67 box version
Data Sheet
LCD2
DIGITAL LOAD LIMITING DEVICE
  • Suitable for lifting systems
  • RS232 and RS485 ports
  • 1 logic input, 3 relay outputs
  • Mounting on Omega/DIN rail for back panel or junction box
  • Limiting the load in dual safety redundant systems
  • Limiting the load in more-weighing systems
Data Sheet

Google Map

Interactively coordinate proactive e-commerce via process-centric “outside the box“ thinking.

Follow Our Activity

Interactively coordinate proactive e-commerce via process-centric “outside the box“ thinking.